Hermetic plastic box with transparent cover for assembly of SWIFT RAIL/COM weighing indicator and its power supply. Ideal for protection on industrial environments and outdoor applications.
*The SWIFT indicator and the power supply are provided separately.
Specifications
Protection class IP 66 (EN 60529)
Impact resistance IK 07 (EN 50102)
Wall mounting ability
Standard 35 mm DIN rail
Earth terminal pre-assembled
Earth cable entry through four PG7 cable glands and two PG9
Switching Power Supply for DIN rail mounting, universal power 100-240 V AC, output at 24 V DC and 15W which allows connection of 3 SWIFT indicators in the same power supply.
Digital / Analog Load Cell Transmitter Series based on last generation of A/D converters and microprocessors, obtaining a modern, compact and reliable design. It´s fully configurated and calibrated by front panel keyboard, avoids adjustment with potentiometers, reducing the difficulty of start-up, calibration and maintenance. It’s ideal for industrial installations with load cells.
The LOADGUARD is an electronic load limiter with redundant weight control by reading up to two independent signal inputs, from the load cells or load pins. Its output relays act according the alarm programming, weight differences between channels or system failures. The main applications are in the control and overload protection in lifting equipments, cranes and machinery.
Ref. Versions
89147LOADGUARD OPTO 89148LOADGUARD ANALOG OPTO
Specifications
In compliance to standard EN 13849-1:2008, PL-d, category 3, corresponding to Safety Integrity Level SIL 2 IEC 62061.
2 weighing inputs for load cells, connected to two independent ADC and two independent microcontrollers.
Connection up to 4 load cells of 350 Ω per channel (8 load cells of 700 Ω per channel).
4 control relays: Alarm thershold, pre-alarm thershold, maximum load difference between channels and load cell cable break detection.
Display 4 digit 7mm LED and 4 keys for configuration, setting and status messages.
Weighing functions: Weight display, full scale and division settings, zero calibration, gain calibration by mass or mV/V, auto-zero, zerotracking and programmable filters.
Optionally available with dual 4-20mA analogue outputs, redundant, one per weighing channel.
Technical Specifications
Load cell connection
Scale input singal range
-+3.9 mV/V
Input sensitivity
0.2 microV
Resolution
Internal 24 bits and external up to 10.000 divisions on the payload
Linearity error
<0.01% measuring range
Thermal stability
<0.002% F.S./°C
Resolution
Category II
Load cell excitation voltage
87 Ω (4 load cells of 350 Ω, 8 load cells of 700 Ω, per channel)
Outputs:
Logical outputs
4 relay (max 48V DC/AC)
Analogue output (Optional)
2 outputs 4-20mA (1 per channel) of 16 bits of resolution
Power, working condition and mechanical data:
Power supply
10V to 30V DC
Maximum consumption
6W
Temperature range
-20 °C to +50 °C de operating; -20 °C to +60 °C storage
Alphanumeric Weighing Indicator with Graphic Display
Ref. Versions
89400MATRIX II for analog load cells 89400DMATRIX II DIGITAL for digital load cells
Specifications
Alphanumeric Weighing Indicator with graphic monochrome display 240×128 pixels.
OIML R76 & EN 45501 Approved, monorange or multirange.
Calibration and configuration by keyboard and/or remote by communication port.
Single Scale Connection for analog load cells (Ref.89400) or digital load cells (Ref.89400D) enlarged to Double Scale Connection by additional interface boards.
Time & Date.
Several connectivity possibilities:
Two RS-232 ports: Bidirectional for PC communications, printer or remote display.
One RS-485 port: Network communications up to 1200m. Additionally, it’s possible to be connected with external dispositives of digital I/O, analog outputs, relay boards, etc.
One additional free port: to extend the indicator to several fieldbuses.
Integrated front panel alphanumeric keyboard and connector for an external standard PC keybard (PS/2).
Ref. 89400: MATRIX II indicator for analog load cells:
In addition of general characteristics, the MATRIX II version has:
A/D 24 bits, 16 millions internal div.; 100.000 external divisions; 50 reading/sec. Power up to 8 load cells (350 Ω) or up to 16 load cells (700 Ω), at 6 V DC excitation. 6000 div. at 0,6 µV/div.
Minivolt pre-calibration: Allows start-up without mass calibration by entering the load cell nominal capacity and nominal sensitivity mV/V.
Ref. 89400D: MATRIX II DIGITAL indicator for digital load cells:
In addition of general characteristics, the MATRIX II DIGITAL version has:
Power up to 16 digital load cells. Distance between the indicator and the scale up to 1200m.
Digital pre-calibration: Allows start-up without mass calibration thanks to the pre-calibration of digital load cells. Automatic or manual corner adjustment. Individual load cell diagnostic.
Applications
Weighbridge: Software for management of vehicle entrance and exit in plants, with first and second weighing control and database that manages and stores all the information (registration number, products, customers/suppliers, entrances/exits, truck pre-fixed tare values, etc.), as well as the printing of its corresponding tickets and listings. Data stored in a permanent internal battery powered RAM memory. Multilingual: English, French, German, Spanish, Portuguese and Czech.
Industrial:
Weight-Tare.
Piece counting.
Weight accumulation.
Programmable pre-fixed tares.
Dosing
Ref. Optional Accessories
Ref: 89312PC KEYBOARD Ref: 89313MATRIX-PRINTER CABLE (3 Meters) Ref: 89314MATRIX-PC CABLE (3 Meters) Ref: 89401AMPLIATION 2nd SCALE FOR ANALOGUE LOAD CELLS Ref: 89402AMPLIATION 2nd SCALE FOR DIGITAL LOAD CELLS Ref: 89404RS232 OPTO-ISOLATED EXPANSION PORT Ref: 89405RS485 OPTO-ISOLATED EXPANSION PORT Ref: 89406DIGITAL INPUTS / OUTPUTS MODULE Ref: 89407ANALOG OUTPUT MODULE: 0-5V, 0-10V, 0-20mA, 4-20mA Ref: 89409ETHERNET EXPANSION PORT
15 – 20 – 30600 x 600 50 – 75 – 120600 x 600 200 – 350600 x 600 250 – 400800 x 800
Specifications Model 190
Double bending beam load cell
Versions:
190 a (50…400kg): Nickel-plated steel alloy. Silicone sealing, IP 66 (EN 60529) 4000 divisions OIML R60 class C
190 i (15…400kg): Fully stainless steel construction. Hermetically sealed, fully welded, IP 68 (EN 60529) and IP 69K (ISO 20653). 3000 divisions OIMLR60 class C
Measuring element from steel alloy
Single point load cell. High accuracy with off-center loads
Protected against corrosion by nickel-plated treatment
Available in ATEX version (optional). Zone 0-1-2 (gas) and 20-21-22 (dust).
Application Model 190
Industrial platform scales, medium and high capacity