Showing 17–32 of 88 results

Mounting Accessories-74901

74901, 74902, 74903, 74904, 74905, 74911, 74912

Mounting Accessories for Mod. 740 and 740d digital

Self-aligning

(15…50t)

Acc. 74901

(60t)

Acc. 74905

(100…200t)

Acc. 74904

(400t)

Acc. 74911

(600t)

Acc. 74912

Base plate

(15…60t)

Acc. 74903

Upper plate

(15…60t)

Acc. 74902

 

Analog Junction Box

Junction Box for Analog Load Cells

Allows the connectivity of up to 4 or 8 analog load cells to the weighing indicator.

  • Available in plastic or aluminium.
  • Corner trimming potentiometers.
  • Version with surge arrestors for lightning protection.
  • Available ATEX version Zone 0-1-2 (gas) and 20-21-22 (dust).

Cajas suma

Ref. 89053
Junction box up to 4 load cells hermetic plastic
Ref. 89128
Junction box up to 4 load cells over voltage protected- hermetic aluminium
Ref. 89093
Junction box up to 4 load cells hermetic aluminium in ATEX version
Ref. 89002
Junction box up to 8 load cells hermetic plastic
Ref. 89068
Junction box up to 8 load cells over voltage protected- hermetic aluminium
Ref. 89092
Junction box up to 8 load cells hermetic aluminium in ATEX version

Junction Circuits (Circuit board & components only)

Ref. 89069
Junction circuit board up to 4 load cells
Ref. 89129
Junction circuit board up to 4 load cells protected
Ref. 89070
Junction circuit board up to 8 load cells
Ref. 89071
Junction circuit board up to 8 load cells protected

Complements-89144 - Z-KEY: Gateway Ethernet RS-232/RS-485

Complements 89144 – Z-KEY: Gateway Ethernet RS-232/RS-485

Complements

Ref. 89144

Z-KEY is an adapter that allows to easily communicate RS-232 / RS-485 serial devices to an Ethernet network and gives solution to Bridge and Gateway communication for ModBus TCP-IP – Modbus RTU.

Allows configuration through USB or through Webserver.

Ethernet adapter for SWIFT, MATRIX II, SMART, DP 100 and DAT.

Specifications


Power Supply11..40V DC, 19..28V AC (50-60Hz)
Consumption1.5W (24V DC), 2W (24V AC)
Operating Temperature-10ºC.. + 50ºC
Storage Temperature-20ºC.. + 85ºC
Protection degreeIP20
Installation35 mm DIN Rail
ConnectionsRemovable terminal block
Dimentions17.5x100x112mm
Serial PortRS-232 / RS-485 (switchable)
Ethernet PortFast Ethernet 10/100 Mbit/s with RJ45 connector
USB PortMicro USB (only for device configuration)

Operating Modes

  • Remote Serial Port on RS-232/RS-485
  • Bridge Modbus TCP-IP – Modbus RTU
  • Gateway Modbus TCP-IP – Modbus RTU

Complements-89314 - Armored (Rodent Protection) Load Cell Cable

Complements 89314 – Armored (Rodent Protection) Load Cell Cable

Complements

Extension cable with 6 wires (senses), keeping same color code than the load cells.

Coated with stainless steel mesh for rodent protection and exterior transparent jacket. Additional protection to abrasion and EMI/RFI interferences.

Internal: Black PVC, shielded, 6 wires 0.25 mm2, diameter 6 mm.

External: Transparent PVC, armored stainless steel, diameter 9 mm.

Specifications


8913420 m coil
8913550 m coil
89136100 m coil
89143200 m coil

Complements-89319 - 4 Output Relays / 4 Inputs

Complements 89319 – 4 Output Relays / 4 Inputs

Complements

Ref. 89319

This module is a conversion unit that directly connects the logical inputs and outputs of the Smart indicator and provides the user with 4 contact inputs and 4 relay outputs as well as the necessary power supply.

Specifications


POWER
Input voltage230 V AC 50/60 Hz
Fuse250 V, 100 mA
Consumption2.4 W

OPERATING CONDITIONS
Operating temperature range-25ºC…+50ºC
Storage temperature limits-25ºC…+70ºC

INPUTS AND OUTPUTS
Inputs: Maximum voltage24 V DC
Relay outputs230 V AC / 0,2 A
30 V DC / 1A

MECHANICAL CHARACTERISTICS
Size136 x 82 x 57 mm
Weight0.2 kg

Complements-89406 - Digital Inputs / Outputs Module

Complements 89406 – Digital Inputs / Outputs Module

Complements

Specifications

This module is an external board assembled on a DIN rail with:

  • 8 digital contact relay outputs, with several functions like: level indication or alarms (setpoints), barriers and traffic lights control atweighbridge, valve control for dosing, etc.
  • 8 digital inputs: for connection to external pannels of push buttons or to plc, to activate funtions such as zero, tare, printing, and the external signals needed for a dosing control
  • 8 relays 230 V AC/0,2 A or 30 V DC/1 A, with LEDs to indicate the state.
  • 8 inputs (max. 24 V DC) with LEDs to indicate the state.
  • Power supply: 12 – 28 V DC / 2.5 W.
  • Connection to Matrix II (COM3 or COM4) by a high speed RS-485 bus (115200 bps) with communication status LEDs.
  • MATRIX II indicator admits up to 15 modules in the same RS-485 bus.
  • Assembly on standard 35 mm DIN rail.

Complements-89407 - Analog Output Module

Complements 89407 – Analog Output Module

Complements

Specifications

This module is an external board assembled on a DIN rail with:

  • Analog output: 0-5V, 0-10V, 0-20mA or 4-20mA.
  • Power supply: 12 – 28 V DC / 2.5 W.
  • Connection to Matrix II (COM3 or COM4) by a high speed RS-485 bus (115200 bps) with communication status LEDs.
  • MATRIX II indicator admits up to 2 modules in the same RS-485 bus (one per installed scale).
  • Assembly on standard 35 mm DIN rail.

Complements-89409 - Ethernet Expansion Port

Complements 89409 – Ethernet Expansion Port

Complements

Specifications

  • TCP/IP Ethernet port for MATRIX II.
  • Allows the connection of the MATRIX II to a standard Ethernet LAN for its remote control and the reading of the weights of the connected scales.
  • 10Base-T technology compatible with 100/1000Mbps networks.
  • Connection via standard Ethernet twisted pair cable with RJ45 connectors.
  • Star topology, via hub or switch.
  • Automatic detection of the module when mounted in the MATRIX II.
  • Configurable IP address.
  • Communication via sockets using the same commands as the serial ports.