Showing all 14 results

Complements-89144 - Z-KEY: Gateway Ethernet RS-232/RS-485

Complements 89144 – Z-KEY: Gateway Ethernet RS-232/RS-485

Complements

Ref. 89144

Z-KEY is an adapter that allows to easily communicate RS-232 / RS-485 serial devices to an Ethernet network and gives solution to Bridge and Gateway communication for ModBus TCP-IP – Modbus RTU.

Allows configuration through USB or through Webserver.

Ethernet adapter for SWIFT, MATRIX II, SMART, DP 100 and DAT.

Specifications


Power Supply11..40V DC, 19..28V AC (50-60Hz)
Consumption1.5W (24V DC), 2W (24V AC)
Operating Temperature-10ºC.. + 50ºC
Storage Temperature-20ºC.. + 85ºC
Protection degreeIP20
Installation35 mm DIN Rail
ConnectionsRemovable terminal block
Dimentions17.5x100x112mm
Serial PortRS-232 / RS-485 (switchable)
Ethernet PortFast Ethernet 10/100 Mbit/s with RJ45 connector
USB PortMicro USB (only for device configuration)

Operating Modes

  • Remote Serial Port on RS-232/RS-485
  • Bridge Modbus TCP-IP – Modbus RTU
  • Gateway Modbus TCP-IP – Modbus RTU

Complements-89314 - Armored (Rodent Protection) Load Cell Cable

Complements 89314 – Armored (Rodent Protection) Load Cell Cable

Complements

Extension cable with 6 wires (senses), keeping same color code than the load cells.

Coated with stainless steel mesh for rodent protection and exterior transparent jacket. Additional protection to abrasion and EMI/RFI interferences.

Internal: Black PVC, shielded, 6 wires 0.25 mm2, diameter 6 mm.

External: Transparent PVC, armored stainless steel, diameter 9 mm.

Specifications


8913420 m coil
8913550 m coil
89136100 m coil
89143200 m coil

Complements-89319 - 4 Output Relays / 4 Inputs

Complements 89319 – 4 Output Relays / 4 Inputs

Complements

Ref. 89319

This module is a conversion unit that directly connects the logical inputs and outputs of the Smart indicator and provides the user with 4 contact inputs and 4 relay outputs as well as the necessary power supply.

Specifications


POWER
Input voltage230 V AC 50/60 Hz
Fuse250 V, 100 mA
Consumption2.4 W

OPERATING CONDITIONS
Operating temperature range-25ºC…+50ºC
Storage temperature limits-25ºC…+70ºC

INPUTS AND OUTPUTS
Inputs: Maximum voltage24 V DC
Relay outputs230 V AC / 0,2 A
30 V DC / 1A

MECHANICAL CHARACTERISTICS
Size136 x 82 x 57 mm
Weight0.2 kg

Complements-89406 - Digital Inputs / Outputs Module

Complements 89406 – Digital Inputs / Outputs Module

Complements

Specifications

This module is an external board assembled on a DIN rail with:

  • 8 digital contact relay outputs, with several functions like: level indication or alarms (setpoints), barriers and traffic lights control atweighbridge, valve control for dosing, etc.
  • 8 digital inputs: for connection to external pannels of push buttons or to plc, to activate funtions such as zero, tare, printing, and the external signals needed for a dosing control
  • 8 relays 230 V AC/0,2 A or 30 V DC/1 A, with LEDs to indicate the state.
  • 8 inputs (max. 24 V DC) with LEDs to indicate the state.
  • Power supply: 12 – 28 V DC / 2.5 W.
  • Connection to Matrix II (COM3 or COM4) by a high speed RS-485 bus (115200 bps) with communication status LEDs.
  • MATRIX II indicator admits up to 15 modules in the same RS-485 bus.
  • Assembly on standard 35 mm DIN rail.

Complements-89407 - Analog Output Module

Complements 89407 – Analog Output Module

Complements

Specifications

This module is an external board assembled on a DIN rail with:

  • Analog output: 0-5V, 0-10V, 0-20mA or 4-20mA.
  • Power supply: 12 – 28 V DC / 2.5 W.
  • Connection to Matrix II (COM3 or COM4) by a high speed RS-485 bus (115200 bps) with communication status LEDs.
  • MATRIX II indicator admits up to 2 modules in the same RS-485 bus (one per installed scale).
  • Assembly on standard 35 mm DIN rail.

Complements-89409 - Ethernet Expansion Port

Complements 89409 – Ethernet Expansion Port

Complements

Specifications

  • TCP/IP Ethernet port for MATRIX II.
  • Allows the connection of the MATRIX II to a standard Ethernet LAN for its remote control and the reading of the weights of the connected scales.
  • 10Base-T technology compatible with 100/1000Mbps networks.
  • Connection via standard Ethernet twisted pair cable with RJ45 connectors.
  • Star topology, via hub or switch.
  • Automatic detection of the module when mounted in the MATRIX II.
  • Configurable IP address.
  • Communication via sockets using the same commands as the serial ports.

Complements-89458 - Mounting Box

Complements 89458 – Mounting Box

Complements

Acc. 89458

Hermetic plastic box with transparent cover for assembly of SWIFT RAIL/COM weighing indicator and its power supply. Ideal for protection on industrial environments and outdoor applications.

*The SWIFT indicator and the power supply are provided separately.

Specifications

  • Protection class IP 66 (EN 60529)
  • Impact resistance IK 07 (EN 50102)
  • Wall mounting ability
  • Standard 35 mm DIN rail
  • Earth terminal pre-assembled
  • Earth cable entry through four PG7 cable glands and two PG9