Additional information
Technical Documentation | https://www.utilcell.es/wp-content/uploads/2016/07/En-De_DS_DAT_Utilcell.pdf |
---|
Digital / Analog Load Cell Transmitter Series based on last generation of A/D converters and microprocessors, obtaining a modern, compact and reliable design. It´s fully configurated and calibrated by front panel keyboard, avoids adjustment with potentiometers, reducing the difficulty of start-up, calibration and maintenance. It’s ideal for industrial installations with load cells.
89076DAT 400
89076PDAT 400 Option Profibus
89076DDAT 400 Option Devicenet
89079DAT 500
89079PDAT 500 Option Profibus
89079DDAT 500 Option Devicenet
Power requirements: | ||
---|---|---|
Input voltage | 24V DC± 15% | |
Power consumption | 7,5W | |
Isolation | Class II | |
Category | Category II | |
Environmental: | ||
Operating Temperature | -10 a +40 °C (+14 a +104 °F) | |
Storage Temperature | -20 a +50 °C (-4 a +122 °F) | |
Relative Humidity | 85% non-condensing | |
Display: | ||
Type | 6 – digit red LED, 7 segment of 14 mm (0,55”) high | |
Status LED’s | 4 Red LED’s | |
Keyboard | 4 Keys (tactile feedback) | |
Performance: | ||
Excitation Voltage | 5 V fixed, short circuit proof | |
Load Current | 85 mA (six 350 Ω load cells) | |
Conversion Rate | 50 updates/second (no filtering) | |
Resolution | 60.000 counts | |
Sensitivity | 0,2 µV / count | |
Linearity | < 0,01 % of F.E. | |
Temperature Creep | < 0,001% of F.S. / °C | |
A/D Converter | 24 Bits | |
Signal Input Range | -0,5mV/V to +3,5 mV/V (-3,9mV/V a +3,9 mV/V opcional) | |
Filter | 0,1 Hz a 25 Hz selectable | |
Increment Size | x1, x2, x5, x10, x20, x50 | |
Decimal Point | 0.0, 0.00, 0.000 | |
Calibration Methods | Computer interface or via front panel | |
Analog Output (Isolated): | ||
Type | 16 bit D/A conversion | |
Voltage | 0-5 and 0-10 V DC (10 KΩ min load) | |
Current | 0-20 and 4-20 mA (300 Ω max load) | |
Linearity | < 0,012% of full scale | |
Temperature Creep | < 0,001 % of F.E. / °C | |
Inputs & Outputs: | ||
2 Logic Inputs | Opto-isolated, 24 V DC PNP (requires ext.power supply) | |
2 Logic Outputs | Solid-state Opto-relays, (maximum load 24 V DC/100 mA each) | |
Serial Output | RS-232, RS-422 or RS-485 | |
Standard Protocols | ASCII, Modbus RTU according PI-Mbus-300* MODICON guide | |
Baud Rate | 2400, 9600, 19200, 38400 y 115.200 selectable | |
Enclosure | DAT 400 | DAT 500 |
Overall Dimensions | 106 x 90 x 58 mm (LxAxP) | 96 x 48 x 139 mm (LxAxP) |
Mounting | DIN Rail | Panel |
Enclosure | ABS | ABS |
Protection (front) | IP20 | IP20 |
Weight | 280g | 310g |
Wiring Connections | Terminal blocks (pitch = 5mm) | Terminal blocks (pitch = 5mm) |
Panel drill | 92 x 44 mm |
Technical Documentation | https://www.utilcell.es/wp-content/uploads/2016/07/En-De_DS_DAT_Utilcell.pdf |
---|